Applications

Process instrumentation in practice

  • Comprehensive process knowledge on a wide range of industrial applications
  • Applications library with more than 300 detailed application reports and notes
  • Customer references, success stories and practical examples for all industries

Filter

324 applications
Industries
Measured media
Product category
Solution category
Application No.
Title
Related products

High-accuracy crude oil flow measurement in a LACT system

Application Note | Oil & Gas

  • Integration of Coriolis flowmeters for Lease Automatic Custody Transfer (LACT) units
  • Mass flow and density measurement without the need for recalibration or maintenance
  • Robust straight-tube design reduces wear and enhances meter durability

Verification of flow rates in a water supply line

Application Note | Water & Wastewater

  • Fast and flexible flow monitoring in a main water distribution line
  • Non-invasive flow measurement on a tar coated pipe with cement liner
  • Use of a portable, battery-powered ultrasonic clamp-on flowmeter with Bluetooth® connectivity

Level measurement of a water sump at a sewage treatment plant

Application Note | Water & Wastewater

  • Reliable measurement of wastewater levels at a sewage pumping station
  • Economical 80 GHz radar provides high measuring dynamics for rapid level changes
  • Non-contact level measurement in a wet well prone to flooding

Level measurement of leachate from sewage sludge humification

Application Note | Water & Wastewater

  • Monitoring of a process water tank to control pumps and agitator
  • Replacement of an ultrasonic level sensor with a robust and long-term stable 80 GHz radar
  • Reliable level measurement independent of wind and weather conditions
  • Quick commissioning via mobile app and Bluetooth® connection

Flow monitoring of wastewater for a sewage treatment plant

Application Note | Water & Wastewater

  • Redundant, non-invasive verification of inline flowmeters and pump capacity
  • Ultrasonic clamp-on flow measurement of sewage at the inlet of a wastewater treatment plant
  • Cost-effective service tool to identify failed pumps or flow instrumentation

Clamp-on flow measurement of coolants for an induction furnace

Application Report | Iron, Steel & Metal

  • Safe operation of an electric furnace for a hot-dip galvanising line
  • Limit value monitoring of demineralised water for cooling purposes
  • Reliable monitoring of the cooling process using non-invasive ultrasonic clamp-on flowmeters
  • Fast measurement response time increases energy efficiency and improves production cycles

Flow measurement of cooling brine in a refrigeration system

Application Note | Refrigeration

  • Temporary flow monitoring to collect measurement data for calculation purposes
  • Use of ultrasonic clamp-on flowmeter for measuring corrosive salt water
  • Flexible, non-invasive installation without process interruption and risk of leakage

Flow control of well water for rapid decarbonisation

Application Report | Chemical

  • Decarbonisation using fast reactors in the production of demineralised water
  • Use of a smart meter valve to precisely increase raw water quantities
  • Improved control quality thanks to automated workflows; no more manual intervention required
  • Reduced maintenance and operating costs thanks to redundancy and extended valve test times

Flow control of liquid waste for a waste-to-energy plant

Application Note | Power Generation

  • Ensuring a safe and environmentally friendly combustion process when co-firing liquid waste
  • Use of a smart meter valve for precise flow control of liquid waste to maintain optimum incineration conditions
  • Space-saving installation of an all-in-one instrument featuring flow, pressure and temperature measurement, control functionality and computing power
  • Seamless integration into PLC via PROFINET; no additional control loop programming necessary

Clamp-on flow measurement for pump performance monitoring

Application Note | Chemical

  • Reliable readings for monitoring cooling water pump performance at difficult process conditions
  • Ultrasonic clamp-on flow measurement on a large glass reinforced plastic (GRP) pipeline
  • Flexible, battery-powered solution for pump verification at different flow rates

Metering and billing of district heating for the city of České Budějovice

Application Report | Power Generation

  • A nuclear power plant supplies CO2-friendly thermal energy for the municipality
  • 3-path ultrasonic flow measurement is used to determine the thermal energy of hot water
  • Complete solution provides high accuracy metering and billing of large heat quantities

Free chlorine monitoring for a thermal spa resort

Application Note | Health & Wellness industry

  • Efficient dosing of a hypochlorite-based sanitizer to effectively prevent contamination and health risks in thermal pools
  • pH compensated free chlorine (Cl2) measurement for a reliable and automated disinfection process
  • Use of a compact, pre-configured measuring system with a membrane-free disinfection sensor, pH sensor, temperature sensor and integrated flow cell monitoring

Showing 12 of 324

Show more
Email
Contact